RENTERS BEWARE: APARTMENT HVAC CLOSETS CAN BE SOURCES OF MOLD AND DEGRADED IAQ

Furnace on water damaged OSB platform.  The return plenum is located beneath the platform.

Furnace on water damaged OSB platform. The return plenum is located beneath the platform.

A common practice in multi-story apartment and condominium complexes is to house the furnaces in closets that are located on the patio or balcony for each unit. The closets are aligned vertically in each building. Although the orientation is convenient for plumbing access, numerous water damage issues are inherent to this type of HVAC set-up.
Water damage from plugged condensate drain tubes or malfunctioning condensate drain pans is common. Slimy biological growth in PVC tubing and drain pans pan causes overflows. Current or historical overflows from the pans will appear on the sheet metal plenum under the A-coil. Drips and mold growth from malfunctioning units above a closet are commonly apparent as drip stains or growth on the ceiling and walls of the closet.
Water damage caused by freezing and thawing of the AC coils is common in apartment HVAC systems. Filter changes are often left in the hands of uninformed tenants. Plugged filters prevent sufficient air flow to the coil, causing it to freeze. As the coil warms up, the ice thaws, releasing large amounts of water into the return plenum, floor system of the apartment, furnace platform, or furnace closet below the damaged unit.
Another issue associated with stacked HVAC closets is the installation of the furnace on a platform, which is commonly constructed from plywood, drywall, or oriented strand board. When wet, all of these materials support the growth of mold and bacteria, which can produce various toxins. Additionally, the glues and resins in these materials can be liberated when wet.

Ceiling of furnace closet showing water entered from HVAC  closet above.

Ceiling of furnace closet showing water entered from HVAC closet above.

The return plenum in furnace closet systems is located beneath the platform, with the underside of the platform being the top of the plenum, a concrete slab serving as the bottom, and the walls of the platform forming the sides of the plenum. In addition to being difficult to clean, a water damaged common plenum provides both a contaminant source and transport pathway.  Dust mites, insects and their fecal material, garbage, cigarette butts, contaminated chunks of paper, and rodent feces are just a few of the treasures that have been recovered from plenums under furnace platforms.
When damage does occur, the underlying cause of water must be corrected. This involves replacing plugged drain tubing, cleaning drip pans, cleaning coils, and changing filters. For consistency, preventive measures in the form of routine inspections and HVAC maintenance should be the responsibility of the management company or maintenance staff.
Addressing the consequences of the water damage, whether it manifests as biological growth or deteriorated building materials, is imperative to appropriate HVAC hygiene and good indoor air quality. Contaminants on water damaged plywood, OSB, and drywall in the furnace closet and on the furnace platform can cause adverse health effects, whether the growth is active or historical. Once dried, mold and bacteria engage in survival mechanisms that can include toxin production and increased sporulation. When dry, the contaminants are easily liberated into the airstream.  Mold remediation is required when building materials in furnace closets become contaminated. The remediation involves two components (1) removal of the mold or contaminated building material and (2) addressing spores that are released from areas of actual growth. Engineering controls, containment barriers, HEPA filtered air filtration devices, personal protective equipment, HEPA vacuuming, and damp-wiping are all essential for safe and effective remediation in water damaged furnace closets.

Return grille located inside of the apartment behind the furnace platform.  Stains show repeated wetting fo tack strip.

Return grille located inside of the apartment behind the furnace platform. Stains show repeated wetting fo tack strip.

Advertisements

Mold Remediation: Standards of Care are More Important than Regulatory Requirements

Painting over mold is not appropriate remediation

“Since mold is not a regulated contaminant, contractors have the freedom to create their own methods and products to treat or remediate mold – Right”?  This argument, which is often disguised as a question) is frequently touted by inexperienced, ignorant, or unethical mold remediators and remediation wannabe’s.  In asking such a question, they are supposedly seeking my professional opinion.  However, the questioner becomes argumentative when my answer does not agree with the desired response. 

Interestingly, individuals asking this question seldom sustain successful businesses, and often become defendants in negligence lawsuits.  Napoleon Hill in Think and Grow Rich teaches that successful people do not reveal what they hope to hear when asking questions.  Instead, successful people are those that seek truth, have vision, and refuse to accept failure.  Successful mold remediators are those that choose to align themselves with masterminds within industry, professionals that not only provide great services, but work to promote ethics and knowledge.    Ethical contractors seek out the most discerning industrial hygienists for pre and post remediation assessment, and they also insist upon doing a job the right way (source removal and detailed cleaning) regardless of who pays the bill.

State licensing for mold remediation contractors will not halt charlatans who use fear tactics to sell quick (but inappropriate) fixes.   The building industry is an excellent example of how licensing fails the consumer.  Poor construction practices are a primary cause of mold problems in residential and commercial buildings.  Unfortunately, licensed contractors that cause mold problems due to substandard building practices receive little more than a slap on the wrist from the state licensing departments.   

Excellence in the mold remediation industry is achieved by:

  • Hard work, both in job performance and promotion of ethical practices within the industry
  • Consumer education
  • Training
  • Alliances, both within the remediation industry and with sister industries, such as builders, HVAC professionals, engineers, architects, and the medical community
  • Accountability in the form of policing within professional organizations in the indoor air quality industry

DAMMED ICE: MARCH IS TIME TO CHECK THE ATTIC FOR MOLD AND WATER DAMAGE

Dammed Ice

In winter months, they can be spotted throughout the northern regions of the United States.  At first they might seem harmless.  Some even sparkle as the winter sun reflects from the stalactite-like structures.  They are ice dams, and these giant icicles are surefire predictors of damned indoor air quality.

Ice dams are caused when the temperature on the upper part of a roof is warmer than on the lower edges.   The melting snow freezes at the colder lower edges, creating dams in the eaves troughs (gutters).  Problems start when the dammed ice begins to melt, and water backs up under shingles, seeking the paths of least resistance.

Water that backs up under shingles and runs into the attic, insulation, walls, and ceilings often remains undetected.  However, hidden within the wet cavities are feeding frenzies for mold and other nasty microorganisms.  Sustained  moisture causes structural damage, odors, and biological growth.       

Consequences of Dammed Ice  In most regions of the US, ice dams melt before March, and signs of  water damage begin to appear.  Some indicators of water damage from ice damming include:

•             Curling and cupping of shingles

•             Stains on ceilings and walls

•             Stains on the underside of a roof deck

•             Mold growth on wood structures in the attic

Drip stains on the topside of insulation and drywall ceiling

•             Drip stains on insulation in the attic

•             Oxidized nails on the underside of a roof deck

•             Musty or mold type odors

 If signs of damage from ice damming are discovered, a qualified professional should be called upon to evaluate structural damage, assess mold growth,  and develop a safe remediation plan.   A qualified consultant will not only provide recommendations for addressing visible mold and water damage, but will also identify areas that should be evaluated for hidden damage. To prevent cross-contamination during invasive investigations into suspect cavities, personal protection, HEPA-filtration, and partition barriers should be used.   An ounce of prevention is priceless when hidden mold contamination is found, especially in a home with immune compromised individuals.

  Remediation

Effective remediation involves two components: (1) removal of the mold and (2) addressing spores in the air and on surfaces.  Removal of attic mold caused by ice damming typically requires removal of the affected roof decking, as the growth is not limited to visible surfaces.  Trusses, joists, and other wood roof members can usually be cleaned using some type of abrasive cleaning.  One of the best abrasive cleaning methods for attics is dry ice blasting.  This method is not only less labor intensive than sanding or scrubbing, it is more effective because the dry ice freezes the surface of the moldy substrate.  Dry ice blasting also facilitates cleaning of crevices and hard to reach areas.  As with all mold remediation, appropriate containment measures, personal protection, and engineering controls must be employed.

  Remediation after ice damming generally requires removal of the attic insulation.  Insulation that is directly impacted by water loses its efficiency.   Insulation in proximityof mold growth must be removed because of cross-contamination.  Aerosolizing of mold spores, fragments and other propagules that settle onto insulation can cause adverse health effects.  After insulation is removed from an attic, surfaces must be cleaned to remove particulate debris and settled spores.

Removal of attic insulation also allows for a thorough inspection of the topsides of drywall ceilings.  Assessment of staining patterns can provide clues about areas of potential hidden water intrusion into wall cavities.  Drywall with visible mold growth on the topside of ceilings must be removed under appropriate containment.

 Appropriate mold remediation after ice damming is necessary to protect the air quality within an indoor environment and prevent structural damage.  Re-construction after remediation must be executed in a manner to correct the conditions that caused ice damming in the first place.  The most common approaches to preventing dammed ice involve installation of appropriate insulation, ventilation and vapor barriers.  Roofing contractors should provide warranties and be held accountable for these issues.

Mold and ice crystals on the underside of a roof deck

Featured In October Women’s Health: “Beat Bad Air Days”

Women's Health | October 2010

Women's Health | October 2010

Extra! Extra! Read all about it! It’s finally on news stands! We’re featured in the October issue of Women’s Health Magazine. The article, “Beat Bad Air Days”  begins on page 76. The article covers indoor air quality and I have the last word which can be found on page 79.

Connie Morbach To Be Featured In October “Women’s Health” Magazine!

Women's Health | July/August CoverI’m elated to announce I will be featured in the October issue of the nationally published “Women’s Health” magazine. I had the opportunity to speak with Women’s Health writer Kate Bowers giving my views on the importance of indoor air quality: what are the risks of household pollutants and what can people do to improve indoor air quality and more.

I’m excited to declare the CleanliNEST™ Crusade is picking up national steam. Here’s to everyone breathing easier!

Take a moment to check out the free iPhone and iPod Workout App from Women’s Health at the link below. Nice workout tool at an even nicer price!

Click here for the Women’s Health Workout Lite App

From Our Video Archives: Sanit-Air Featured On PBS “The Business Page” Television Program

The nationally recognized Public Broadcasting System affiliate in Detroit, WTVS Channel 56, produced and aired a wonderful local business program titled “The Business Page.” Sanit-Air and our team of environmental IAQ experts and technicians had the distinct pleasure of an extensive feature on “The Business Page.”

Producer Mike Echols narrates this business feature that serves as a nice introduction to the basic understanding of the workings of Sanit-Air and the foundation for our CleaniNEST™ brand and consumer crusade. We hope you find “The Business Page” feature on Sanit-Air informative.

Sanit Air & CleanliNEST™ Featured in Today’s C & G News

Connie Morbach Suited Up Examining Mold

That's me all suited up and taking mold samples...

We’re excited to announce we were featured in today’s C&G News in an insightful feature written by the C and G’s Christa Buchanan. Click on the link to read and learn more: http://www.candgnews.com/Homepage-Articles/2010/06-23-2010/Indoor-contaminants.asp

%d bloggers like this: